Heat Exchangers Heateflex Corporation offers superior temperature controllers for static baths, re-circulation, and single pass applications. Heateflex Corporation has researched the industry's needs and produced fully integrated multifunctional controller/timers with no need for external signal conditioning. Built-in features include: liquid-level control, over-temperature control, and 20 Amp switching.


Heateflex Corporation's patented Power-to-Flow Control® feature varies power to the heater depending on flow rate, and allows for precision temperature control.

  • Benefits
  • Features
  • Specifications
Benefits
  • Self Contained with no external signal conditioning required
  • Built-In liquid level circuitry
  • Direct sensor hookup; Process and Over-temperature thermacouples, liquid-levels
  • Built-In features reduce installation time and wiring

Our Model DT968C is a superior temperature controller and timer for static baths and recirculation application. Heateflex has researched the industry's needs and produced a fully integrated controller/timer with no need for external conditioning.


DT968C Features Include
  • croprocessor Based Temperature Controller & Timer for Static (Constant Temperature Bath) and Recirculation Applications.
  • Controls Bath Temperature with a Standard Three Mode (PID) Control Scheme, with Anti-Reset Windup.
  • Numerous Status and Alarm Functions.
  • Adjustment:
    Cycle Rate: 0-19 Sec.
    Proportional Band: 0.0-19.9°C
    Reset (Integral): 0.1-19.9 Sec.
    Rate (Derivative): 0.1-19.9°C.
    Calibration Offset: ±9.9°C.

DT968B Features Include
  • Microprocessor Based One Pass, Power-To-Flow ControlĀ® Temperature Controller.
  • Power-To-Flow ControlĀ® Varies Power Available to the Heater Depending on the Flow Rate.
  • Flow Resolution: 0.1 GPM.
  • Adjustment:
    Cycle Rate: 0-5 Sec.
    Power Reset (Integral): 1-199 Sec.
    Calibration Offset: ±9.9°C.Non-Contaminating PFA Encapsulated.

Features included in Both Model DT968C and Model DT968B
  • Built-in 20 ampere, photo isolated, solid-state power controller is used to control the heater.
  • Independent high limit circuit powered by isolation transformer on primary side of master relay.
  • Type J over-temperature thermocouple disables internal master relay if over-temperature detected.
  • Two numeric displays allow simultaneous viewing of both Process Temperature and Timer (DT968C) or Process Temperature and Flow (DT968B).
  • 12 key membrane switch keyboard in face panel for user setup and adjustment of the system.
  • Twelve discrete LEDs indicate system and display status.
  • All alarms activate audio tone, alarm status LED, and individual alarm annunciator.
  • Audio tone and LEDs alternate on and off to draw attention to the alarm condition.
  • Password protection of user parameters.
  • Kydex® enclosure with a back printed Lexan® faceplate.
Standard Models:

Model No.

Application

Part No.

Description

DT968C

Recirculating

306850

CT Bath Temperature Controller/Timer, 120VAC

DT968C

Recirculating

306870

CT Bath Temperature Controller/Timer, 208VAC

DT968B

Single Pass

306891

Power-To-Flow Control®, 120VAC

DT968B

Single Pass

306890

Power-To-Flow Control®, 208VAC

©Heateflex Corporation. All Rights Reserved. Content duplication prohibited without permission. Sitemap